Aluminum Extruded Shapes

  • twitter
  • facebook

For consideration of aluminum and aluminum alloy extruded shapes

Here we list the standards of the aluminum and aluminum alloy extruded shapes offered by UACJ, by product number. The listed information is extracted from JIS H4100:2006 (Japanese Standards Association).

Organization that compiles the standards: Japan Aluminium Association

1000 Series

Alloy number Temper(1) Tension test
Thickness of test piece
(mm)
Cross sectional area
(cm2)
Tensile strength
(N/mm2)
Yield strength
(N/mm2)
Elongation(2) (%)
A50mm A
1070 H112 55 or over 15 or over
1060 H112 Between 3 and 30 60 or over 30 or over 25 or over
1050 H112 65 or over 20 or over
1100
1200
H112 75 or over 20 or over

 

2000 Series

Alloy number Temper(1) Tension test
Thickness of test piece
(mm)
Cross sectional area
(cm2)
Tensile strength
(N/mm2)
Yield strength
(N/mm2)
Elongation(2) (%)
A50mm A
2014 O(3) 245 or under 125 or under 12 or over
T4 345 or over 245 or over 12 or over
T42(4) 345 or over 205 or over 12 or over
T6 15 or under 415 or over 365 or over 7 or over 6 or over
Over 15 to 30 440 or over 400 or over 7 or over 6 or over
Over 30 160 or under 470 or over 410 or over 7 or over 5 or over
Over 160 to 200 470 or over 400 or over 6 or over 5 or over
Over 200 to 250 450 or over 380 or over 6 or over
Over 250 to 300 430 or over 365 or over 6 or over
2014 T62(5) 19 or under 410 or over 365 or over 7 or over
Over 19 160 or under 410 or over 365 or over 7 or over
Over 160 to 200 410 or over 365 or over 6 or over
2014 A T6 15 or under 415 or over 365 or over 6 or over
Over 15 to 30 435 or over 370 or over 6 or over
Over 30 to 60 470 or over 400 or over 5 or over
2017 O(3) 245 or under 125 or under 16 or over
T4
T42(4)
700 or under 345 or over 215 or over 12 or over
Over 700 to 1000 335 or over 195 or over 12 or over
2017 A T4 15 or under 380 or over 230 or over 10 or over
Over 15 to 30 380 or over 230 or over 10 or over
2024 O(3) 245 or under 125 or under 12 or over
T3 5 or under 395 or over 290 or over 12 or over
Over 5 to 15 395 or over 290 or over 12 or over
Over 15 to 30 415 or over 305 or over 9 or over
T4 6 or under 390 or over 295 or over 12 or over
Over 6 to 19 410 or over 305 or over 12 or over
Over 19 to 38 450 or over 315 or over 10 or over
Over 38 160 or under 480 or over 365 or over 10 or over
Over 160 to 200 470 or over 335 or over 8 or over
Over 200 to 300 460 or over 315 or over 8 or over
T42(4) 19 or under 390 or over 265 or over 12 or over
Over 19 to 38 390 or over 265 or over 10 or over
Over 38 160 or under 390 or over 265 or over 10 or over
Over 160 to 200 390 or over 265 or over 8 or over
T81 5 or under 440 or over 385 or over 4 or over
Over 5 to 15 440 or over 385 or over 4 or over
Over 15 to 30 450 or over 400 or over 4 or over

 

3000 Series

Alloy number Temper(1) Tension test
Thickness of test piece
(mm)
Cross sectional area
(cm2)
Tensile strength
(N/mm2)
Yield strength
(N/mm2)
Elongation(2) (%)
A50mm A
3003
3203
H112 95 or over 35 or over 22 or over 17 or over

 

5000 Series

Alloy number Temper(1) Tension test
Thickness of test piece
(mm)
Cross sectional area
(cm2)
Tensile strength
(N/mm2)
Yield strength
(N/mm2)
Elongation(2) (%)
A50mm A
5052 H112 175 or over 70 or over
O Between 175 and 245 70 or over 20 or over
5454 H112 130 or under 200 or under 215 or over 85 or over 12 or over
O 130 or under 200 or under Between 215 and 285 85 or over 14 or over
5083 H112 130 or under 200 or under 270 or over 140 or over 12 or over 12 or over
O 38 or under 200 or under Between 275 and 355 120 or over 14 or over
Over 38 to 130 200 or under Between 275 and 355 110 or over 14 or over
5086 H112 130 or under 200 or under 240 or over 95 or over 12 or over
O 130 or under 200 or under Between 240 and 315 95 or over 14 or over

 

6000 Series

Alloy number Temper(1) Tension test
Thickness of test piece
(mm)
Cross sectional area
(cm2)
Tensile strength
(N/mm2)
Yield strength
(N/mm2)
Elongation(2) (%)
A50mm A
6101 T6 (7) Between 3 and 7 195 or over 165 or over 10 or over
Over 7 to 17 195 or over 165 or over 12 or over
Over 17 to 30 175 or over 145 or over 14 or over
T7 Between 3 and 7 135 or over 110 or over 10 or over
6005C T5 6 or under 245 or over 205 or over 8 or over
Over 6 to 12 225 or over 175 or over 8 or over
T6 (7) 6 or under 265 or over 235 or over 8 or over
6005 A T5 8 or under 250 or over 200 or over 8 or over
T6 (7) 6 or under 270 or over 225 or over 8 or over
Over 6 to 10 260 or over 215 or over 8 or over
6060 T4(7) 25 or under 120 or over 60 or over 14 or over
T5 5 or under 160 or over 120 or over 6 or over
Over 5 to 25 140 or over 100 or over 6 or over
T6 (7) 3 or under
Over 3 to 25

190 or over
170 or over
150 or over
140 or over
6 or over
6 or over

6061 O(3) 145 or under 110 or under 16 or over
T4(7) 175 or over 110 or over 16 or over 14 or over
T42 (4) 175 or over 85 or over 16 or over
T6 (7)
T62 (5)
6 or under 265 or over 245 or over 8 or over 7 or over
Over 6 265 or over 245 or over 10 or over
6082 T4 (7) 15 or under 205 or over 110 or over 14 or over 14 or over
T5 15 or under 290 or over 250 or over 8 or over 8 or over
T6 (7) 15 or under 310 or over 260 or over 7 or over 8 or over

 

7000 Series

Alloy number Temper(1) Tension test
Thickness of test piece
(mm)
Cross sectional area
(cm2)
Tensile strength
(N/mm2)
Yield strength
(N/mm2)
Elongation(2) (%)
A50mm A
7204 200 or under 245 or under 145 or under 12 or over
T4 (6) 200 or under 315 or over 195 or over 11 or over
T5 200 or under 325 or over 245 or over 10 or over
T6 200 or under 335 or over 275 or over 10 or over
7003 T5 12 or under 285 or over 245 or over 10 or over
Over 12 to 25 275 or over 235 or over 10 or over
7005 T53 Over 3 to 25 160 or under 345 or over 305 or over 10 or over 9 or over
7020 (8) T6
T5
Over 3.0 to 30 350 or over 290 or over 8 or over 10 or over
7050 T76510 127 or under 545 or over 475 or over 7 or over
T73511 125 or under 200 or under 485 or over 415 or over 8 or over 7 or over
T74511 76 or under 505 or over 435 or over 7 or over
7075 O(3) 275 or under 165 or under 10 or over
T6
T62(5)
6 or under 540 or over 480 or over 7 or over 6 or over
Over 6 to 75 560 or over 500 or over 7 or over
Over 75 to 110 130 or under 560 or over 490 or over 7 or over
Over 130 to 200 540 or over 480 or over 6 or over
Over 110 to 130 200 or under 540 or over 470 or over 6 or over
T73 30 or under 470 or over 400 or over 7 or over

Notes

  • (1) Temper in accordance with JIS H 0001.
  • (2) For elongation, the following two methods were applied with differing gauge lengths. In cases where the client does not provide specific instructions for elongation measurement, A50mm is used.
    In cases where A50mm is not specified, A is used.
    A: % of elongation in gauge length of(S0: Cross sectional area of flat portion)
      A50mm: % of elongation in gauge length of 50mm
  • (3) A material with O for temper is the base for materials with a temper T42 or T62 and in cases where the client requests it, a guarantee of the performance of these materials has to be given.
  • (4) For the mechanical properties of a T42 temper, values are applied in line with a case in which the client has solution heat treated and then naturally age hardened a temper O material.
    However, in a case where, before carrying out solution heat treatment, the client applies some kind of cold working or hot working process, values may be lower than shown.
  • (5) For the mechanical properties of a T62 temper, values are applied in line with a case in which the client has solution heat treated and then artificially age hardened a temper O material.
    However, in a case where, before carrying out solution heat treatment, the client applies some kind of cold working or hot working process, values may be lower than shown.
  • (6) The mechanical properties of a T4 temper have been set using values for a case in which it has been solution heat treated and then naturally age hardened for one month at room temperature (approx. 20˚C) as a standard.
    In cases where tension tests have been carried out before one month of natural age hardening, these tests are carried out using a test piece that has been solution heat treated and then artificially age hardened. This confirms that it meets the tensile properties of a T6 temper and this can replace the guarantee of tensile properties of a T4 temper.
  • (7) Also applies to shapes that have been control-cooled after extrusion.
  • (8) Only applies to solid materials.
Remark 1.
Mechanical properties for measurements outside of the specified range can be mutually agreed by both parties at time of delivery.
2.
1 N/mm2 = 1 MPa